es_headerbild_vario-takk.jpg

vari-takk PRO

Vari-Takk Pro tacker panel system –
One-step installation.


One-step installation of 2.4 m². Also contributes to thermal insulation and improved sound impact. This folding panel is also particularly suitable for laying across larger areas.


System features:

  • Tacker system technology: improved retention force
  • High installation rate
  • Thermal and impact sound insulation from expanded polystyrene high resistance foam EPS-T according to EN 13163
  • Plastic coating with interwoven fibres and 5 cm grid pattern as screed damp proofing according to EN 18560 and for securing the pipes
  • Blunt edge
  • Long-sided 30 mm upper layer overlap
Suitable for duo-flex and tri-o-flex® system heating pipes
14 x 2 mm | 16 x 2 mm | 17 x 2 mm | 20 x 2 mm
Preisliste Fußbodenheizung

Export

Download PDF
Data sheet system panels

Tacker panel system vari-takk PRO

Download PDF


es_system-tackerplatte_vari-takk-pro.png

Product Variants

Type EPS-T 30-3 (DES sm)

Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.68 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 20
Impact sound reduction ΔLw,R
29 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 27 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
4 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
no
Article number
4001217
Packaging unit
1,000 x 1,200 x 480 mm
19.2 m²
8 Panels
VPE/Palette76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.68 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 20
Impact sound reduction ΔLw,R
29 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 27 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
4 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
no
Article number
4001217
Packaging unit
1,000 x 1,200 x 480 mm
19.2 m²
8 Panels
VPE/Palette76.80 m2
add to watchlist

Type EPS-T 30-2 (DES sg)

Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.77 m² K/W 
Thermal conductivity λD
0.039 W/mK (WLG 040)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4003778
Packaging unit
1,000 x 1,200 x 480 mm
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.77 m² K/W 
Thermal conductivity λD
0.039 W/mK (WLG 040)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4003778
Packaging unit
1,000 x 1,200 x 480 mm
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist

Type EPS-T 30-2 (DES sg) SV

Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.88 m² K/W 
Thermal conductivity λD
0,034 W/mK (WLS 035)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1.000 x 2.400 mm x 480 mm
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4032192
Packaging unit
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.88 m² K/W 
Thermal conductivity λD
0,034 W/mK (WLS 035)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1.000 x 2.400 mm x 480 mm
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4032192
Packaging unit
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist

Type EPS 20-2 (DES SG)

Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.46 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 18 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
yes
Article number
4026795
Packaging unit
1,000 x 1,200 x 400 mm
24 m²
10 Panels
VPE/Palette
120 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.46 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 18 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
yes
Article number
4026795
Packaging unit
1,000 x 1,200 x 400 mm
24 m²
10 Panels
VPE/Palette
120 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.68 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 20
Impact sound reduction ΔLw,R
29 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 27 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
4 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
no
Article number
4001217
Packaging unit
1,000 x 1,200 x 480 mm
19.2 m²
8 Panels
VPE/Palette76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.77 m² K/W 
Thermal conductivity λD
0.039 W/mK (WLG 040)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4003778
Packaging unit
1,000 x 1,200 x 480 mm
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.88 m² K/W 
Thermal conductivity λD
0,034 W/mK (WLS 035)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1.000 x 2.400 mm x 480 mm
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4032192
Packaging unit
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.46 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 18 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
yes
Article number
4026795
Packaging unit
1,000 x 1,200 x 400 mm
24 m²
10 Panels
VPE/Palette
120 m2
add to watchlist

Product Variants

Special variant

Type EPS-T 30-2 (DES sg)

Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.88 m² K/W 
Thermal conductivity λD
0,034 W/mK (WLS 035)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1.000 x 2.400 mm x 480 mm
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4032192
Packaging unit
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.88 m² K/W 
Thermal conductivity λD
0,034 W/mK (WLS 035)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1.000 x 2.400 mm x 480 mm
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4032192
Packaging unit
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist

Type EPS 20-2 (DES sg)

Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.46 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 18 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
yes
Article number
4026795
Packaging unit
1,000 x 1,200 x 400 mm
24 m²
10 Panels
VPE/Palette
120 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.46 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 18 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
yes
Article number
4026795
Packaging unit
1,000 x 1,200 x 400 mm
24 m²
10 Panels
VPE/Palette
120 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.88 m² K/W 
Thermal conductivity λD
0,034 W/mK (WLS 035)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 28 mm 
Panel size
1.000 x 2.400 mm x 480 mm
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
single-layer
Higher traffic load
yes
Article number
4032192
Packaging unit
19.2 m²
8 Panels
VPE/Palette
76.80 m2
add to watchlist
Technical data
ÖNORM
B 6000: EPS-T 650 kg/m²
Thermal resistance RD
0.46 m² K/W 
Thermal conductivity λD
0.044 W/mK (WLG 045)
Dynamic stiffness
SD 30
Impact sound reduction ΔLw,R
27 dB*
Fire behavior RtF
E (EN 13501-1)
Panel thickness
dL - c = 18 mm 
Panel size
1,000 x 2,400 mm 
Max. load capacity
5 kPa (acc. to EN 13163)
Type of installation
two-ply
Higher traffic load
yes
Article number
4026795
Packaging unit
1,000 x 1,200 x 400 mm
24 m²
10 Panels
VPE/Palette
120 m2
add to watchlist

*acc. to DIN 4109-34: 2016-07 for areal screed mass ≥ 120 kg/m²